Full-Service Roofing | Prim, AR
Roof repairs, full replacements, storm damage, gutters, metal roofing, flat roofs. Prim Roofing & Maintenance covers it all in Prim. Licensed, insured, manufacturer-certified.
Roof Replacement
Your roof replacement includes a full-system install: ice and water shield at eaves, valleys, and penetrations; synthetic underlayment across the entire deck; aluminum drip edge at rake and eave; starter strip with sealant; architectural shingles with 130+ mph wind rating; and continuous ridge vent for proper attic ventilation. We also install new pipe boots and vent flashing on every penetration.
Get a Free Quote โRoof Repair
Missing shingles from wind damage expose the underlayment to UV degradation. If the underlayment is compromised, water intrusion follows the next rain. We don't just replace the missing shingle. We pull back surrounding courses, inspect the underlayment for UV damage and nail holes, replace compromised sections, and weave new CertainTeed Landmark or IKO Cambridge shingles into the existing field. Proper repair, not a patch.
Get a Free Quote โStorm Damage Repair
Wind damage and hail damage look different and require different documentation. Our HAAG-trained inspectors know what adjusters look for: granule displacement patterns, fractures in the shingle mat, seal failures, cracked ridge caps. Proper documentation is why our claims get approved.
Get a Free Quote โNew Roof Installation
New construction underlayment per IRC R905 and ASTM D226 (felt) or ASTM D6757 (synthetic). Ice barrier per ASTM D1970 required at eaves in climate zones with average January temperature below 25ยฐF. We install ice and water shield regardless. It's cheap insurance against ice dams and wind-driven rain. Drip edge per IRC R905.2.8.5 on eave and rake edges. Proper starter strip with factory sealant for wind resistance from day one.
Get a Free Quote โMetal Roofing
Standing seam metal is the longest-lasting residential roofing material you can install. 40-60 year lifespan, virtually zero maintenance, and it sheds hail and debris better than any shingle. Our Prim metal crews install residential and commercial standing seam, corrugated, and metal shingle profiles.
Get a Free Quote โShingle Roofing
CertainTeed Landmark PRO with NailTrak technology and Max Def color blends. Dimensional color depth that mimics natural cedar. Algae-resistant with StreakFighter technology. Class A fire rating, ASTM D3462 compliant, rated to 110 mph per ASTM D3161 Class F (Landmark PRO IR rated to 130 mph). 5-Star SureStart Plus warranty when installed by CertainTeed SELECT ShingleMaster. That's us. The warranty covers 100% of material and labor costs for 20 years with declining coverage for 30 more.
Get a Free Quote โFlat Roofing
TPO single-ply membrane in 60-mil or 80-mil thickness, fully adhered or mechanically attached over minimum R-25 polyiso insulation. Hot-air welded seams tested with a probe at every joint. We install per NRCA and manufacturer specifications with tapered ISO insulation creating minimum 1/4" per foot positive drainage. Ponding water is the number one cause of flat roof failure in Prim. Tapered insulation eliminates it. FM 4473 rated systems available for hail-prone areas. Fully warranted by Carlisle, Firestone, or GAF.
Get a Free Quote โCommercial Roofing
We install Carlisle SynTec and Firestone TPO membrane systems in 60-mil and 80-mil thickness over minimum R-25 polyiso insulation (more in climate zones requiring it). Seams hot-air welded at 900ยฐF+ and tested with a seam probe. Fully adhered systems for wind uplift zones per FM I-90 or I-120. Mechanically attached for re-roofs over existing insulation. NRCA member, trained per manufacturer specifications.
Get a Free Quote โGutter Installation
We hang gutters with hidden hangers screwed into the rafter tails or fascia board every 24 inches max. No spike-and-ferrule, no exposed hardware. Proper pitch is 1/4" per 10 feet toward each downspout. Too flat and water sits. Too steep and it looks wrong.
Get a Free Quote โRoof Inspection
Annual inspections catch small problems early. A cracked pipe boot is a $150 repair. A year of water leaking through that crack causes $3,000+ in ceiling, insulation, and drywall damage. We recommend an inspection every 2-3 years for newer roofs, annually for roofs over 15 years.
Get a Free Quote โEmergency Roof Repair
Emergency tarping is step one. Stop the water. We secure heavy-duty poly tarps over the damaged area using 2x4 nailer boards attached to the deck. Once the immediate threat is contained, we schedule the permanent repair within 48-72 hours.
Get a Free Quote โSkylight Installation
Solar-powered VELUX skylights qualify for the 30% federal solar tax credit through 2032. The blinds and opening mechanism run on a built-in solar panel. No wiring needed. We install them in Prim all the time. Good light, fresh air, and a tax write-off.
Get a Free Quote โ